|
ATLAS Offline Software
|
Go to the documentation of this file.
8 #ifndef XAODEGAMMA_EGAMMAENUMS_H
9 #define XAODEGAMMA_EGAMMAENUMS_H
13 namespace EgammaParameters {
295 #endif // XAODEGAMMA_EGAMMAENUMS_H
@ unconverted
unconverted photon
@ NumberOfVertexMatchProperties
maximum number of enums
@ convMatchDeltaPhi2
difference between the cluster phi and the phi of the second track of the vertex extrapolated to the ...
@ ehad1
E leakage into 1st sampling of had calo (CaloSampling::HEC0 + CaloSampling::TileBar0 + CaloSampling::...
@ e233
uncalibrated energy (sum of cells) of the middle sampling in a rectangle of size 3x3 (in cell units e...
@ deltaPhi0
difference between the cluster phi (presampler) and the eta of the track extrapolated to the presampl...
@ e033
uncalibrated energy (sum of cells) in presampler in a 3x3 window in cells in eta X phi
@ deltaPhi3
difference between the cluster eta (3rd sampling) and the eta of the track extrapolated to the 3rd sa...
@ e2ts1
2nd max in strips calc by summing 3 strips
@ asy1
uncorr asymmetry in 3 strips in the 1st sampling
@ e235
uncalibrated energy (sum of cells) of the middle sampling in a rectangle of size 3x5
@ ecore
core energy in em calo E(core) = E0(3x3) + E1(15x2) + E2(5x5) + E3(3x5)
@ deltaEta0
difference between the cluster eta (presampler) and the eta of the track extrapolated to the presampl...
@ deltaEta2
difference between the cluster eta (second sampling) and the eta of the track extrapolated to the sec...
@ ethad1
transverse energy in the first sampling of the hadronic calorimeters behind the cluster calculated fr...
ICaloAffectedTool is abstract interface for tools checking if 4 mom is in calo affected region.
@ deltaPhiRescaled3
difference between the cluster eta (3rd sampling) and the eta of the track extrapolated to the 3rd sa...
@ f1core
E1(3x1)/E = fraction of the energy reconstructed in the first longitudinal compartment of the electro...
@ wtots1
shower width is determined in a window detaxdphi = 0,0625 ×~0,2, corresponding typically to 20 strips...
@ deltaPhi1
difference between the cluster eta (1st sampling) and the eta of the track extrapolated to the 1st sa...
@ e333
uncalibrated energy (sum of cells) of the third sampling in a rectangle of size 3x3
@ f3
fraction of energy reconstructed in 3rd sampling
@ e1152
uncalibrated energy (sum of cells) in strips in a 15x2 window in cells in eta X phi
@ deltaPhiFromLastMeasurement
difference between the cluster phi (sampling 2) and the eta of the track extrapolated from the last m...
@ ethad
ET leakage into hadronic calorimeter with exclusion of energy in CaloSampling::TileGap3.
@ f1
E1/E = fraction of energy reconstructed in the first sampling, where E1 is energy in all strips belon...
@ pos7
Difference between the track and the shower positions: sum_{i=i_m-7}^{i=i_m+7}E_i x (i-i_m) / sum_{i=...
@ emins1
energy reconstructed in the strip with the minimal value between the first and second maximum
@ poscs2
relative position in eta within cell in 2nd sampling
@ e011
uncalibrated energy (sum of cells) in presampler in a 1x1 window in cells in eta X phi
@ doubleSi
two tracks, both with Si hits
@ deltaEta3
difference between the cluster eta (3rd sampling) and the eta of the track extrapolated to the 3rd sa...
@ deltaPhiRescaled2
difference between the cluster phi (second sampling) and the phi of the track extrapolated to the sec...
@ NumberOfShowerShapes
maximum number of enums
@ deltaPhiRescaled0
difference between the cluster phi (presampler) and the eta of the track extrapolated to the presampl...
@ convMatchDeltaPhi1
difference between the cluster phi and the phi of the first track of the vertex extrapolated to the s...
@ doubleSiTRT
two tracks, only one with Si hits
@ singleTRT
one track only, no Si hits (TRT only)
@ e377
uncalibrated energy (sum of cells) of the middle sampling in a rectangle of size 7x7
@ poscs1
relative position in eta within cell in 1st sampling
@ singleSi
one track only, with Si hits
@ deltaPhi2
difference between the cluster phi (second sampling) and the phi of the track extrapolated to the sec...
@ barys1
barycentre in sampling 1 calculated in 3 strips
@ deltaPhiRescaled1
difference between the cluster eta (1st sampling) and the eta of the track extrapolated to the 1st sa...
@ convMatchDeltaEta1
difference between the cluster eta and the eta of the first track of the vertex extrapolated to the s...
@ e255
uncalibrated energy (sum of cells) of the middle sampling in a rectangle of size 5x5
@ e337
uncalibrated energy (sum of cells) of the third sampling in a rectangle of size 3x7
@ r33over37allcalo
1-ratio of energy in 3x3 over 3x7 cells; E(3x3) = E0(1x1) + E1(3x1) + E2(3x3) + E3(3x3); E(3x7) = E0(...
@ convMatchDeltaEta2
difference between the cluster eta and the eta of the second track of the vertex extrapolated to the ...
@ e277
uncalibrated energy (sum of cells) of the middle sampling in a rectangle of size 7x7
@ NumberOfTrackMatchProperties
maximum number of enums
@ widths1
same as egammaParameters::weta1 but without corrections on particle impact point inside the cell
@ doubleTRT
two tracks, none with Si hits (TRT only)
@ weta1
shower width using +/-3 strips around the one with the maximal energy deposit: w3 strips = sqrt{sum(E...
@ e132
uncalibrated energy (sum of cells) in strips in a 3x2 window in cells in eta X phi
@ NumberOfVertexConversionTypes
maximum number of types
@ Eratio
(emaxs1-e2tsts1)/(emaxs1+e2tsts1)
@ e237
uncalibrated energy (sum of cells) of the middle sampling in a rectangle of size 3x7
@ deltaEta1
difference between the cluster eta (first sampling) and the eta of the track extrapolated to the firs...
@ f3core
E3(3x3)/E fraction of the energy reconstructed in the third compartment of the electromagnetic calori...
@ e2tsts1
energy of the cell corresponding to second energy maximum in the first sampling
@ widths2
same as egammaParameters::weta2 but without corrections on particle impact point inside the cell
@ e335
uncalibrated energy (sum of cells) of the third sampling in a rectangle of size 3x5
@ emaxs1
energy of strip with maximal energy deposit
@ fracs1
shower shape in the shower core : [E(+/-3)-E(+/-1)]/E(+/-1), where E(+/-n) is the energy in ± n strip...
@ pos
difference between shower cell and predicted track in +/- 1 cells
@ weta2
the lateral width is calculated with a window of 3x5 cells using the energy weighted sum over all cel...