ATLAS Offline Software
|
@ etcone30_ptcorrected
pT-leakage corrections applied to ET in a cone with half-opening angle 0.30
@ ehad1
E leakage into 1st sampling of had calo (CaloSampling::HEC0 + CaloSampling::TileBar0 + CaloSampling::...
@ e233
uncalibrated energy (sum of cells) of the middle sampling in a rectangle of size 3x3 (in cell units e...
@ etcone15_ptcorrected
pT-leakage corrections applied to ET in a cone with half-opening angle 0.15
@ depth
pointing depth of the shower as calculated in egammaqgcld
@ topoetcone20
Topo-cluster ET-sum.
@ etcone30_corrected
pT-leakage + ED corrections applied to ET in a cone with half-opening angle 0.30
@ e033
uncalibrated energy (sum of cells) in presampler in a 3x3 window in cells in eta X phi
@ etcone20_corrected
pT-leakage + ED corrections applied to ET in a cone with half-opening angle 0.20
@ etcone20_ptcorrected
pT-leakage corrections applied to ET in a cone with half-opening angle 0.20
@ e2ts1
2nd max in strips calc by summing 3 strips
@ asy1
uncorr asymmetry in 3 strips in the 1st sampling
@ e235
uncalibrated energy (sum of cells) of the middle sampling in a rectangle of size 3x5
@ topoetcone40_corrected
Topo cluster pT-leakage + ED corrections applied to ET in a cone with half-opening angle 0....
@ ecore
core energy in em calo E(core) = E0(3x3) + E1(15x2) + E2(5x5) + E3(3x5)
@ zvertex
pointing z at vertex reconstructed from the cluster
@ ptcone20
Track isolation.
@ ethad1
transverse energy in the first sampling of the hadronic calorimeters behind the cluster calculated fr...
@ etcone
Calorimeter isolation.
ICaloAffectedTool is abstract interface for tools checking if 4 mom is in calo affected region.
setRcore setEtHad setFside pt
@ f1core
E1(3x1)/E = fraction of the energy reconstructed in the first longitudinal compartment of the electro...
@ topoetcone40_ptcorrected
Topo cluster pT-leakage corrections applied to ET in a cone with half-opening angle 0....
@ wtots1
shower width is determined in a window detaxdphi = 0,0625 ×~0,2, corresponding typically to 20 strips...
@ etcone40_ptcorrected
pT-leakage corrections applied to ET in a cone with half-opening angle 0.40
@ etap
pointing eta reconstructed from the cluster (first and second sampling)
@ e333
uncalibrated energy (sum of cells) of the third sampling in a rectangle of size 3x3
@ f3
fraction of energy reconstructed in 3rd sampling
@ e1152
uncalibrated energy (sum of cells) in strips in a 15x2 window in cells in eta X phi
@ ethad
ET leakage into hadronic calorimeter with exclusion of energy in CaloSampling::TileGap3.
@ etcone25
ET in a cone with half-opening angle 0.25, with exclusion of a window of size 7x5 in electromagnetic ...
setEt setPhi setE277 setWeta2 setEta1 e2tsts1
#define AUX_VARIABLE(VAR,...)
Convenience macro for declaring an auxiliary variable.
@ etcone20
Calorimeter isolation.
@ pos7
Difference between the track and the shower positions: sum_{i=i_m-7}^{i=i_m+7}E_i x (i-i_m) / sum_{i=...
@ emins1
energy reconstructed in the strip with the minimal value between the first and second maximum
@ poscs2
relative position in eta within cell in 2nd sampling
@ e011
uncalibrated energy (sum of cells) in presampler in a 1x1 window in cells in eta X phi
@ nucone20
number of tracks in a cone with half-opening angle 0.2
@ e377
uncalibrated energy (sum of cells) of the middle sampling in a rectangle of size 7x7
@ etcone40_corrected
pT-leakage + ED corrections applied to ET in a cone with half-opening angle 0.40
@ etcone15
ET in a cone with half-opening angle 0.15, with exclusion of a window of size 7x5 in electromagnetic ...
setEt setPhi setE277 weta2
@ poscs1
relative position in eta within cell in 1st sampling
@ etcone25_ptcorrected
pT-leakage corrections applied to ET in a cone with half-opening angle 0.25
@ etcone35_ptcorrected
pT-leakage corrections applied to ET in a cone with half-opening angle 0.35
@ barys1
barycentre in sampling 1 calculated in 3 strips
@ etcone35
ET in a cone with half-opening angle 0.35, with exclusion of a window of size 7x5 in electromagnetic ...
@ nucone30
number of tracks in a cone with half-opening angle 0.2
@ e255
uncalibrated energy (sum of cells) of the middle sampling in a rectangle of size 5x5
@ e337
uncalibrated energy (sum of cells) of the third sampling in a rectangle of size 3x7
@ r33over37allcalo
1-ratio of energy in 3x3 over 3x7 cells; E(3x3) = E0(1x1) + E1(3x1) + E2(3x3) + E3(3x3); E(3x7) = E0(...
@ errz
associated error on zvertex
@ widths1
same as egammaParameters::weta1 but without corrections on particle impact point inside the cell
@ weta1
shower width using +/-3 strips around the one with the maximal energy deposit: w3 strips = sqrt{sum(E...
@ e132
uncalibrated energy (sum of cells) in strips in a 3x2 window in cells in eta X phi
@ e237
uncalibrated energy (sum of cells) of the middle sampling in a rectangle of size 3x7
@ f3core
E3(3x3)/E fraction of the energy reconstructed in the third compartment of the electromagnetic calori...
@ widths2
same as egammaParameters::weta2 but without corrections on particle impact point inside the cell
@ e335
uncalibrated energy (sum of cells) of the third sampling in a rectangle of size 3x5
@ nucone40
number of tracks in a cone with half-opening angle 0.2
@ emaxs1
energy of strip with maximal energy deposit
@ fracs1
shower shape in the shower core : [E(+/-3)-E(+/-1)]/E(+/-1), where E(+/-n) is the energy in ± n strip...